Preface | |
| |
| |
Acknowledgments | |
| |
| |
| |
Introduction | |
| |
| |
Why Roofs Fail | |
| |
| |
Lessons from History | |
| |
| |
Need for Research and Standards | |
| |
| |
| |
The Roof as a System | |
| |
| |
Design Factors | |
| |
| |
Basic Roof Components | |
| |
| |
Disastrous Combinations | |
| |
| |
Constructing the Roof | |
| |
| |
Divided Responsibility | |
| |
| |
Unified Responsibility | |
| |
| |
Performance Criteria | |
| |
| |
References | |
| |
| |
| |
Draining the Roof | |
| |
| |
Why Drain the Roof? | |
| |
| |
Life-Cycle Costing Example | |
| |
| |
How to Drain the Roof | |
| |
| |
Drainage Design | |
| |
| |
Draining an Existing Roof | |
| |
| |
Alerts | |
| |
| |
Design | |
| |
| |
Maintenance | |
| |
| |
References | |
| |
| |
| |
Structural Deck | |
| |
| |
Deck Materials | |
| |
| |
Design Factors | |
| |
| |
Slope | |
| |
| |
Deflection | |
| |
| |
Dimensional Stability | |
| |
| |
Moisture Absorption | |
| |
| |
Anchorage of Components | |
| |
| |
Deck Surface and Joints | |
| |
| |
Steel Decks | |
| |
| |
Recommendations for Steel Decks | |
| |
| |
Alerts | |
| |
| |
Design | |
| |
| |
Field | |
| |
| |
References | |
| |
| |
| |
Thermal Design | |
| |
| |
Thermal Insulating Materials | |
| |
| |
Rigid Board Insulation | |
| |
| |
Poured-in-Place Insulating Concrete Fill | |
| |
| |
Design Factors | |
| |
| |
Strength Requirements | |
| |
| |
Moisture Absorption | |
| |
| |
Venting | |
| |
| |
Dimensional Stability | |
| |
| |
Tapered Insulation | |
| |
| |
Anchoring Insulation to the Deck | |
| |
| |
Solid Bearing for Insulation Boards | |
| |
| |
Refrigerated Interiors | |
| |
| |
Effects of Increased Insulation Thickness | |
| |
| |
Joint Taping | |
| |
| |
Double-Layered Insulation | |
| |
| |
Principles of Thermal Insulation | |
| |
| |
Moisture Reduction of Insulating Value | |
| |
| |
Heat-Flow Calculation | |
| |
| |
Heat Gain or Loss | |
| |
| |
Cool Roofs | |
| |
| |
Principles of Radiant Heat Transfer | |
| |
| |
Complicating Factors | |
| |
| |
California Cool | |
| |
| |
Seasonal Factors | |
| |
| |
ANSI/IESNA | |
| |
| |
ASHRAE Standard 90.1 | |
| |
| |
Alerts | |
| |
| |
Design | |
| |
| |
Field | |
| |
| |
References | |
| |
| |
| |
Vapor Control | |
| |
| |
Fundamentals of Vapor Flow | |
| |
| |
Techniques for Controlling Moisture | |
| |
| |
General Ventilation | |
| |
| |
Vapor Retarder | |
| |
| |
Self-Drying Roof System | |
| |
| |
The Futility of Topside Venting | |
| |
| |
Theory of Vapor Migration | |
| |
| |
Diffusion | |
| |
| |
Air Leakage | |
| |
| |
Air Barriers | |
| |
| |
Sample Vapor-Retarder Calculation | |
| |
| |
Alerts | |
| |
| |
Design | |
| |
| |
Field | |
| |
| |
References | |
| |
| |
| |
Wind Uplift | |
| |
| |
Historical Background | |
| |
| |
Mechanics of Wind-Uplift Pressure | |
| |
| |
Basic Wind-Speed Determinants | |
| |
| |
Building Shape, Size, and Enclosure | |
| |
| |
Determining Final Wind-Uplift Pressure | |
| |
| |
Procedure for Calculating Design Wind Pressure | |
| |
| |
Design Example: Anchored System | |
| |
| |
SEI/ASCE 7-02 versus FM Global | |
| |
| |
Perimeter Flashing Failures | |
| |
| |
Wind-Uplift Mechanics on Ballasted Roofs | |
| |
| |
Gravel Blowoff and Scour | |
| |
| |
Wind-Uplift Design for Ballasted, Single-Ply Roof Assemblies | |
| |
| |
Basic Ballasted Wind-Design Systems | |
| |
| |
PMR Wind Design | |
| |
| |
Retroactive Redesign | |
| |
| |
Design Example for Ballasted, Loose-Laid System | |
| |
| |
Wind-Uplift Testing | |
| |
| |
Laboratory Tests | |
| |
| |
Field Wind-Uplift Tests | |
| |
| |
Repair Procedures after Wind-Uplift Failure | |
| |
| |
Mechanical Fasteners | |
| |
| |
Alerts | |
| |
| |
General | |
| |
| |
Design | |
| |
| |
Field | |
| |
| |
References | |
| |
| |
| |
Fire Resistance | |
| |
| |
Nature of Fire Hazards | |
| |
| |
External Fire Resistance | |
| |
| |
Internal Fire Hazards | |
| |
| |
Below-Deck Fire Tests and Standards | |
| |
| |
Flame-Spread Test | |
| |
| |
FM Fire Classification | |
| |
| |
Time-Temperature Ratings | |
| |
| |
Fire Rating versus Insulating Efficiency | |
| |
| |
Building Code Provisions | |
| |
| |
Alert | |
| |
| |
| |
Historical Background of Contemporary Roof Systems | |
| |
| |
Built-up Bituminous Membranes | |
| |
| |
The First-Generation Single-Ply Pioneers | |
| |
| |
The Cold-Process Dead End | |
| |
| |
The Second-Generation Success | |
| |
| |
New Roof Systems | |
| |
| |
Modified Bitumens | |
| |
| |
| |
Elements of Built-up Membranes | |
| |
| |
Membrane Materials | |
| |
| |
Roofing Bitumens | |
| |
| |
Incompatibility of Asphalt and Coal Tar Pitch | |
| |
| |
Coal Tar Pitch versus Asphalt | |
| |
| |
Felts | |
| |
| |
Surfacing | |
| |
| |
Smooth-Surfaced Membrane | |
| |
| |
Mineral-Surfaced Roll Roofing | |
| |
| |
Heat-Reflective Surfacings | |
| |
| |
Built-up Membrane Specifications | |
| |
| |
Shingling of Felts | |
| |
| |
Coated Base Sheet | |
| |
| |
Phased Application | |
| |
| |
Temporary Roofs | |
| |
| |
Joints in Built-up Membranes | |
| |
| |
Membrane Performance Standards | |
| |
| |
BUR Failure Modes | |
| |
| |
Blisters | |
| |
| |
Splitting | |
| |
| |
Ridging | |
| |
| |
Membrane Slippage | |
| |
| |
Alerts | |
| |
| |
General | |
| |
| |
Design | |
| |
| |
Field | |
| |
| |
References | |
| |
| |
| |
Modified-Bitumen Membranes | |
| |
| |
Historical Background | |
| |
| |
Modified-Bitumen Materials | |
| |
| |
Rubberizing Polymers | |
| |
| |
Reinforcement | |
| |
| |
Surfacing | |
| |
| |
Modified-Bitumen Specifications | |
| |
| |
Modified-Bitumen Flashings | |
| |
| |
Performance Criteria for Modified Bitumens | |
| |
| |
Modified-Bitumen Failure Modes | |
| |
| |
Defective Lap Seams | |
| |
| |
Checking | |
| |
| |
Shrinkage | |
| |
| |
Blistering | |
| |
| |
Delamination | |
| |
| |
Slippage | |
| |
| |
Splitting | |
| |
| |
Alerts | |
| |
| |
General | |
| |
| |
Design | |
| |
| |
Field | |
| |
| |
References | |
| |
| |
| |
Elastomeric Membranes | |
| |
| |
Basic Material | |
| |
| |
Field Seaming | |
| |
| |
Flashings | |
| |
| |
Mechanically Fastened Systems | |
| |
| |
Elastomeric Failure Modes | |
| |
| |
Alerts | |
| |
| |
General | |
| |
| |
Design | |
| |
| |
Field | |
| |
| |
References | |
| |
| |
| |
Weldable Thermoplastics | |
| |
| |
Materials | |
| |
| |
Historical Background | |
| |
| |
Flashings | |
| |
| |
Failure Modes | |
| |
| |
Alerts | |
| |
| |
References | |
| |
| |
| |
Flashings | |
| |
| |
Flashing Functions and Requirements | |
| |
| |
Materials | |
| |
| |
Base Flashing Materials | |
| |
| |
Counterflashing Materials | |
| |
| |
Principles of Flashing Design | |
| |
| |
Eliminating Penetrations | |
| |
| |
Reducing Openings | |
| |
| |
Flashing Elevation | |
| |
| |
Differential Movement | |
| |
| |
Flashing Contours and Cants | |
| |
| |
Flashing Connections | |
| |
| |
Specific Flashing Conditions | |
| |
| |
Edge Details | |
| |
| |
Vertical Flashings | |
| |
| |
Roof Penetrations | |
| |
| |
Expansion-Contraction Joints | |
| |
| |
Water Conductors | |
| |
| |
Flashing Failures | |
| |
| |
Sagging | |
| |
| |
Ponding Leakage | |
| |
| |
Diagonal Wrinkling | |
| |
| |
Postconstruction Damage | |
| |
| |
Alerts | |
| |
| |
General | |
| |
| |
Design | |
| |
| |
Field | |
| |
| |
Standard Details | |
| |
| |
| |
Protected Membrane Roofs and Waterproofed Decks | |
| |
| |
Why the Protected Membrane Roof? | |
| |
| |
How PMR Changes Component Requirements | |
| |
| |
PMR Design and Construction | |
| |
| |
Drain Location | |
| |
| |
PMR Flashings | |
| |
| |
PMR Insulation Performance Requirements | |
| |
| |
Thermal Quality of PMR Insulation | |
| |
| |
Refinements in Locating PMR Insulation | |
| |
| |
Surfacing Protected Membrane Roofs | |
| |
| |
Life-Cycle Costing | |
| |
| |
Waterproofed Deck Systems | |
| |
| |
Structural Decks | |
| |
| |
Membranes | |
| |
| |
Protection Boards | |
| |
| |
Drainage Design | |
| |
| |
Aggregate Percolation versus Open Subsurface Drainage | |
| |
| |
Insulation | |
| |
| |
Flashing | |
| |
| |
Wearing Surface Design | |
| |
| |
Plaza "Furniture" | |
| |
| |
Detailing | |
| |
| |
Flood Testing | |
| |
| |
Alerts (for PMRs) | |
| |
| |
Alerts (for Waterproofed Decks) | |
| |
| |
Design | |
| |
| |
Field | |
| |
| |
References | |
| |
| |
| |
Sprayed Polyurethane | |
| |
| |
Historical Background | |
| |
| |
Materials | |
| |
| |
Polyurethane Foam | |
| |
| |
Membrane Coating | |
| |
| |
Surfacing Aggregate | |
| |
| |
Detailing SPF Systems | |
| |
| |
Application Requirements | |
| |
| |
Foam Application | |
| |
| |
Coating Application | |
| |
| |
Quality Assurance | |
| |
| |
Maintenance | |
| |
| |
Alerts | |
| |
| |
General | |
| |
| |
Design | |
| |
| |
Application | |
| |
| |
Maintenance | |
| |
| |
References | |
| |
| |
| |
Metal Roof Systems | |
| |
| |
Historical Background | |
| |
| |
Metal Roof Concepts and Terminology | |
| |
| |
Design Factors | |
| |
| |
Thermal Movement | |
| |
| |
Drainage | |
| |
| |
Condensation | |
| |
| |
Penetrations | |
| |
| |
Wind-Uplift Resistance | |
| |
| |
Corrosion Protection | |
| |
| |
Metal Roofing Accessories | |
| |
| |
Thermal Insulation | |
| |
| |
Underlayments | |
| |
| |
Vapor Retarders | |
| |
| |
Detailing Metal Roofing | |
| |
| |
Metal-Roof-System Defects | |
| |
| |
Aesthetic Problems | |
| |
| |
Functional Problems | |
| |
| |
Metal Roof Evaluation | |
| |
| |
References | |
| |
| |
| |
Field Inspections | |
| |
| |
Quality Assurance | |
| |
| |
QA Inspections | |
| |
| |
Application Checklists | |
| |
| |
Visual Roof Surveys | |
| |
| |
Nondestructive Moisture Detection | |
| |
| |
Benefits of Nondestructive Moisture Detection | |
| |
| |
Limitations | |
| |
| |
Principles of Nondestructive Moisture Detection | |
| |
| |
Other Moisture-Detection Techniques | |
| |
| |
References | |
| |
| |
| |
Reroofing and Repair | |
| |
| |
Re-covering or Tearoff-Replacement? | |
| |
| |
Investigation and Analysis | |
| |
| |
Preliminary Investigation | |
| |
| |
Leak-Detection Technique | |
| |
| |
Visual Inspection and Analysis | |
| |
| |
Field-Test Cuts | |
| |
| |
Large-Scale Moisture Surveys | |
| |
| |
Assessment for Remedial Action | |
| |
| |
New Performance Criteria | |
| |
| |
Reroofing Specifications | |
| |
| |
Isolating the New Membrane | |
| |
| |
Flashings | |
| |
| |
Surface Preparation of Existing Membrane | |
| |
| |
Retrofit Metal Roofing | |
| |
| |
Alerts | |
| |
| |
For Replacement Bituminous Roof Membranes | |
| |
| |
For Loose-Laid Synthetic Single-Ply Membranes | |
| |
| |
For Sprayed Polyurethane Foam (Plus Fluid-Applied Coating) | |
| |
| |
| |
Roof-System Specifications | |
| |
| |
Specifications and Drawings | |
| |
| |
Drawing Requirements | |
| |
| |
Specification Requirements | |
| |
| |
Writing Style | |
| |
| |
Specifying Methods | |
| |
| |
Master Specification | |
| |
| |
Division of Responsibility | |
| |
| |
Temporary Roofing | |
| |
| |
Special Requirements | |
| |
| |
Specifying New Roofing Products | |
| |
| |
Quality Assurance | |
| |
| |
Coordination | |
| |
| |
Test Cuts | |
| |
| |
Alerts | |
| |
| |
General | |
| |
| |
New Products | |
| |
| |
General Field | |
| |
| |
Technical | |
| |
| |
References | |
| |
| |
| |
Roofing Guarantees and Warranties | |
| |
| |
Manufacturer's Bond | |
| |
| |
Manufacturer's Warranty | |
| |
| |
Analyzing the Warranty | |
| |
| |
Warranty Checklist | |
| |
| |
Roofer's Guarantee | |
| |
| |
Roof-Maintenance Program | |
| |
| |
Glossary of Roofing-Related Terms | |
| |
| |
| |
ASTM International Conversion Factors and Roofing Standards | |
| |
| |
| |
Index and Abstracts of ASTM Test Methods for Roofing Materials | |
| |
| |
Index | |